摘要:

相对辐射定标是获得各类光学遥感卫星传感器的高精度观测产品的必备条件,由于受发射震动、在轨空间环境变化等因素以及传感器自身衰减的影响,传感器在轨响应状态会随时间发生衰减和漂移,单一相对辐射定标方法无法保障卫星传感器在特定时间的探元响应一致性。本文以光学卫星传感器全生命周期影像辐射质量保障为目标,主要研究了光学卫星传感器在轨生命周期内高频率、高定标精度的常态化相对辐射定标方法,并总结了当前常用的相对辐射定标精度评估方法,评估了各定标方法的指标以及应用场景。利用珞珈一号01星(LJ1-01)夜光传感器获取的影像进行在轨暗电流、和在轨均匀场地定标实验和验证,珠海一号02组高光谱卫星影像被用来实施和验证统计定标和偏航辐射定标方法,并耦合多种定标方法实现常态化辐射定标。实验结果表明:各种定标方法处理后影像的条纹系数小于0.25%,图像相对标准差均优于3.00%;多种定标方法相互结合的常态化辐射定标方法实现了多种定标方法的优势最大化,完成常见传感器的高精度在轨标定。

关键词: 光学卫星, 响应一致性, 相对辐射定标, 暗电流定标, 星上定标, 在轨均匀场地定标, 统计定标, 偏航辐射定标

Abstract:

The relative radiometric calibration of optical satellite sensors minimizes the inconsistency of linear or non-linear responses of the sensor detectors with different incident radiances. It is a prerequisite of various types of high-quality remote sensing products. The response of on-orbit sensor changes with time due to factors such as launch induced vibration, space environment changes, and the sensor degradation. However, both the one-time relative radiometric calibration and single relative radiometric calibration methods cannot guarantee the consistency in responses of satellite sensors at a specific time. Therefore, the normalized on-orbit radiometric calibration method with high frequency and high precision for satellite sensors is necessary for better applications of remote sensing products. In this study, we focused on the image radiometric calibration of the whole life cycle of optical satellite sensors, and the high-frequency, high-precision, wide or full dynamic range on-orbit relative radiometric calibration methods. Also, we summarized the existing accuracy evaluation methods of relative radiometric calibration methods as well as their application scenarios. In our study, the LJ1-01 nighttime satellite images were used to verify the dark current and uniform field calibration methods. The Zhuhai1 group 02 hyperspectral satellite images were used to verify the statistical calibration and yawing radiometric calibration methods as well as the normalized radiometric calibration method integrated by a variety of calibration methods. Our results show that the stripe coefficient was less than 0.25%, with a higher relative standard deviation of the images (3.00%) than images processed by each individual evaluation method. The normalized radiometric calibration method integrated by various calibration methods maximizes the advantages of individual calibration methods and is capable of high precision on-orbit calibration for common sensors, which further guarantees the quality of remote sensing products and meets the requirements of quantitative application.

Key words: optical satellites, response consistency, relative radiometric calibration, the dark current calibration, the on-board calibration, the uniform sites calibration, the statistical calibration, the yaw calibration

下载说明

·如果您发现该资源不能下载,请通知管理员.gissky@gmail.com

·为确保下载的资源能正常使用,请使用[WinRAR v3.8]或以上版本解压本站资源,缺省解压密码www.gissky.net ,如果是压缩文件为分卷多文件,请依次下载每一个文件,并按照顺序命名为1.rar,2.rar,3.rar...,然后鼠标右击1.rar解压.

·为了保证您快速的下载速度,我们推荐您使用[网际快车]等专业工具下载.

·站内提供的资源纯属学习交流之用,如侵犯您的版权请与我们联系.